ANALIZADORES DE CHIMENEAS
  Full Extractive Probe - PRO400
This probe uses extractive technology for wet basis measurement

The PRO400 Full Extractive Probe handles the toughest environments while offering significant advantages over typical full extractive probes. The Full Extractive Probe meets EPA requirements, as defined in 40 CFR 75 and 40 CFR 60, using extractive technology for wet basis measurement, continuous emissions monitoring.

15C
Product Details

APPLICATIONS:
Utility boilers, pulp mills, waste-to-energy facilities, incinerators, turbines, refineries, petro-chemical plants, and co-generation facilities.

NON-STANDARD OPTIONS:


Probe Barrel:
• Heated Probe Barrel
• Teflon lined 316SS (applications below 135°C (275°F)
• Hastelloy 276

Heated Filter Assembly:
• Special material aor reactive gases (HCL, NH3, THC)

Mouting Flange:
• Size other than 4"

Enlcosure:
• Other

Specifications

Probe Barrel 1" Schdule 40 Stainless Steel pipe, typical length 52" (132cm)
Heater Filter 0.1 micron fiber high temperature element, controlled at 287°C (550°F)
Enclosure NEMA 4 Enclosure
Mouting Flange Stainless Steel, 4" (10.36cm), 150 psi
Probe Assembly Weight 62 lbs. (28.2 kg)
Instrument Air Requirement Clean, dry air at -40°C (-40°F) dew point, 60 psi minimum for purge
Power Requirements 120 VAC, 300 watts
Operating Ambient Temp Range -20°C (-4°F) to +50°C (122°F)
Maximum Process Temperature 600°C (1112°F)
 

 
Dock Norte Argentina:
Cochabamba 477. Buenos Aires (1150AAE). Argentina. Tel: 54.11.4.307.8363 - 54.11.4.361.5807