Multi Gas Portable Gas Detection Solutions for various applications
The Genesis Toxigen Three Gas Monitor detects oxygen, combustible and one toxic gas: NH3, Cl2, NHCN, NO, NO2, SO2 or hydride (PH3, AsH3, SiH4)
Product Details
Thermo Electron's Genesis personal portable three-gas toxigen monitor detects combustible,O2, and one of the following "Toxigen" gases: NH3, Cl2, HCN, NO, NO2, SO2, hydride (PH3, AsH3, SiH4).
The Genesis can be used in four configurations:
• Diffusion
• Built-in sample pump
• Hand-aspirated pump
• Extender cable
Features
• Optional internal datalogging
• TWA/STEL alarms
• Simple one-button calibration
• Interchangeable 3-AA alkaline batteries or rechargeable NiHy
• Peak, STEL and TWA readings
• RF resistant
Range of Gases Detected
| Gases |
Formula |
Standard Range |
| Ammonia |
NH3 |
0 - 100 ppm in 1 ppm increments |
| Carbon Monoxide |
CO |
0 - 250 ppm in 1 ppm increments |
| Chlorine |
Cl2 |
0 - 9.9 ppm in 0.1 ppm increments |
| Combustible |
LEL |
0 - 100% LEL in 1% LEL increments |
| Hydrogen Cyanide |
HCN |
0 - 30 ppm in 1 ppm increments |
| Hydrogen Sulfide |
H2S |
0 - 200 ppm in 1 ppm increments |
| Nitric Oxide |
NO |
0 -100 ppm in 1 ppm increments |
| Nitrogen Dioxide |
NO2 |
0 - 9.9 ppm in 0.1 ppm increments |
| Oxygen |
O2 |
0 - 30.0% Vol in 0.1% increments |
| Phosphine |
PH3 |
0 - 3.00 ppm in 0.01 ppm increments |
| Sulfur Dioxide |
SO2 |
0 -9.9 ppm in 0.1 ppm increments |
Sensor Compatability Chart
| |
CO |
H2S |
CL2 |
HCN |
NH3 |
NO |
NO2 |
SO2 |
PH3 |
| CO |
|
YES |
YES |
YES |
YES |
YES |
YES |
YES |
YES |
| H2S |
YES |
|
|
YES |
|
YES |
|
YES |
YES |
| CL2 |
YES |
|
|
|
|
YES |
|
|
YES |
| HCN |
YES |
YES |
|
|
YES |
YES |
|
|
YES |
| NH3 |
YES |
|
|
YES |
|
|
YES |
|
YES |
| NO |
YES |
YES |
|
YES |
|
|
YES |
|
YES |
| NO2 |
YES |
|
YES |
|
YES |
YES |
|
YES |
YES |
| SO2 |
YES |
YES |
|
|
|
|
YES |
|
YES |
| PH3 |
YES |
YES |
YES |
YES |
YES |
YES |
YES |
YES |
|
Specifications
| Gas Type |
Cl2, CO, HCN, H2S, O2, NH3, NO, NO2, PH3, SO2 |
| Sensors |
Catalytic - Combustible Gases (Electrochemical - Toxic Gases) |
| Sampling Method |
Diffusion (Standard) / Sample-Draw (optional built-in pump) / Extender cable (optional 20 ft or 50 ft) |
| Power Source |
3-AA Alkaline or NiHy battery pack |
| Battery Life |
Alkaline: 22 hours without pump or 11 hours with pump (NiHy: 16 hours without pump or 8 hours with pump) |
| Intrinsic Safety |
UL Classified, CSA and LCIE / EEX Certified |
| Sensor Warranty |
2 year (CO, H2S, O2, LEL) 1 year (all other toxics) |
| Instrument Warranty |
2 year (materials & workmanship) |