|
|
| DATALOGGERS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Serie LNX - Model 600DL |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() Brochure Keep your equipment updated • Data Acquisition device up to 255 sensors • Programmable 255 alarms • Data Concentrator System (TerminalWEB) • Updatable via USB • Multi-Language ![]() LNX DataLOGGER is a hardware and software combined for acquisition, storing, processing and transmitting data streamed by up to twenty sensors in six/ twelve/eighteen analog input channels (LNX Series) or sixteen analog input channels, including a pulse counter. LNX series have a plaque allowing the calibration, instruments alarms, and other plaque that allow communication via AIR. LNX DataLOGGER can be independently used to handle a sensor, analyze multiple sensors, laboratory analytical sensors, industrial processes control system or security work. DataLOGGER enables a real time visualization of 255 simultaneous sensors. Since DataLOGGER has from 6 acquisition channels, any number of sensors can share the same input analog channel thus elaborating data collected in another time range or with a different elaboration type. Also, these virtual sensors can be shown on display or remain invisible, but sending elaborated data to the database. Operative Capacity The LNX DataLOGGER has 6 analog inputs with programmable gain, and electrical scales from 0 to 0.08125 volts up to 0 to 5 volts, 7 digital inputs or outputs, and one Pulse Counter. Data elaboration is performed at sensor level, having the possibility to configure a different time interval for each one. Main Characteristics Main characteristics are described below within their main groups: ![]() • Up to 25 programmable analog inputs • Up to 40 digital inputs/outputs • Up to 5 Pulse input • Up to 255 simultaneous sensors Storage • Local data storage in SQL Server® engine • Remote data storage via LAN local area network in central concentrator • Wireless remote data storage in central concentrator • User-defined storage interval Protocols • MODBUS via TCP • SERIAL Calibration • Simultaneous calibration of up to four sensors. • Programmed and unattended automatic calibration. • Calibration advances visualization at different phases of each one of the sensor. • Reports of the calibration records and results and changes introduced in the drift correction settings. • Calibration history. • Charts drawing during calibration. • Solenoid valves opening and closing control. • Transmission of calibration records to central concentrator. Alarms • 255 configurable alarms. • Real time alarms. • Average alarms. • Relay switching option when alarm fires. • Software and hardware alarms detection. • Alarms transmission to central concentrator. • Alarms history record. Connectivity • Historical records transmission to central concentrator. • Instant values transmission to central concentrator. • Calibrations records transmission to central concentrator. • Alarms records transmission to central concentrator. • Current Campaign and Point transmission to central concentrator. • DataLOGGER full remote control. Charts drawing • Real time charts drawing of every sensor operation at data collection and calibration. Updating • Updatable via USB Internationalization • Multi-language interface Applications • Environmental monitoring • CEM • Meteorological stations • Lab sensor • Industrial processes • Labor security and hygiene Differents Scenarios
Single Monitor Stations
Scenario A.1 Scenario A.2 Scenario A.3 Scenario A.4 Scenario A.5 Scenario A.6
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dock Norte Argentina: Cochabamba 477. Buenos Aires (1150AAE). Argentina. Tel: 54.11.4.307.8363 - 54.11.4.361.5807 |