DATALOGGERS
  Serie LNX - Model 600DL

Vea esta pagina en español
15C


Brochure
Download brochure

Keep your equipment updated
Download Update

Data Acquisition device up to 255 sensors
Programmable 255 alarms
Data Concentrator System (TerminalWEB)
Updatable via USB
Multi-Language

15C
Product Description

LNX DataLOGGER is a hardware and software combined for acquisition, storing, processing and transmitting data streamed by up to twenty sensors in six/ twelve/eighteen analog input channels (LNX Series) or sixteen analog input channels, including a pulse counter.

LNX series have a plaque allowing the calibration, instruments alarms, and other plaque that allow communication via AIR.

LNX DataLOGGER can be independently used to handle a sensor, analyze multiple sensors, laboratory analytical sensors, industrial processes control system or security work.

DataLOGGER enables a real time visualization of 255 simultaneous sensors. Since DataLOGGER has from 6 acquisition channels, any number of sensors can share the same input analog channel thus elaborating data collected in another time range or with a different elaboration type.

Also, these virtual sensors can be shown on display or remain invisible, but sending elaborated data to the database.

Operative Capacity

The LNX DataLOGGER has 6 analog inputs with programmable gain, and electrical scales from 0 to 0.08125 volts up to 0 to 5 volts, 7 digital inputs or outputs, and one Pulse Counter.

Data elaboration is performed at sensor level, having the possibility to configure a different time interval for each one.

Main Characteristics

Main characteristics are described below within their main groups:

15C
Inputs and Outputs
• Up to 25 programmable analog inputs
• Up to 40 digital inputs/outputs
• Up to 5 Pulse input
• Up to 255 simultaneous sensors

Storage
• Local data storage in SQL Server® engine
• Remote data storage via LAN local area network in central concentrator
• Wireless remote data storage in central concentrator
• User-defined storage interval

Protocols
• MODBUS via TCP
• SERIAL

Calibration
• Simultaneous calibration of up to four sensors.
• Programmed and unattended automatic calibration.
• Calibration advances visualization at different phases of each one of the sensor.
• Reports of the calibration records and results and changes introduced in the drift correction settings.
• Calibration history.
• Charts drawing during calibration.
• Solenoid valves opening and closing control.
• Transmission of calibration records to central concentrator.

Alarms
• 255 configurable alarms.
• Real time alarms.
• Average alarms.
• Relay switching option when alarm fires.
• Software and hardware alarms detection.
• Alarms transmission to central concentrator.
• Alarms history record.

Connectivity
• Historical records transmission to central concentrator.
• Instant values transmission to central concentrator.
• Calibrations records transmission to central concentrator.
• Alarms records transmission to central concentrator.
• Current Campaign and Point transmission to central concentrator.
• DataLOGGER full remote control.

Charts drawing
• Real time charts drawing of every sensor operation at data collection and calibration.

Updating
• Updatable via USB

Internationalization
• Multi-language interface

Applications
• Environmental monitoring
• CEM
• Meteorological stations
• Lab sensor
• Industrial processes
• Labor security and hygiene

Differents Scenarios









Product Specifications
Sensors Management
• Data Management and processing from up to 255 Sensors
• Virtual Calculated Sensors via MicroC built-in language
• MODBUS PLC Management
• Serial RS232 Sensors Management
• MultiGas CEMS ready
• ThermoFisher i Series connection via TCP
• Analog Instruments via Industrial grade 24 bits resolution built-in board
• Pulse Counter Instruments via built-in board
• Davis Instruments Vantage Pro 2 management via USB
• Relays and valves switching via built-in board
Hardware
• Redundant data storage in built-in RAID Mirrored Backup SATA drives of 160 Gb
• Up to 25 Analog Inputs of 24 bits resolution
• Up to 40 Digital I/O
• Up to 5 Pulse Counters
• 5 external 12 Volts terminals
• 2 RS232 Serial ports
• Ready to plug external relays modules (optional)
• Ready to plug external wireless communication module (optional)
• Ready to plug 56k analog modem (optional)
• Ready to plug external rack mount TouchScreen
• Industrial rack mount in 1 unit height
Remote Control
3 modes of Remote Control via LNX Connector
  • Safe Support Mode
  • Read-Only Control Mode
  • Full Control Mode
Safe Remote Monitoring
Remote monitoring and data processing via TerminalWEB™
Data Processing and Actions
• Average user defined storage data interval
• Flags Data validation
• Relay switching (open/close) when average data is lower or higher than value
   E.g. Switch relay 1 (open valve) if 15 minutes average of CO is > 6.8 ppm
• Send email and/or SMS when average data is lower or higher than value
Alarms Processing and Actions
• Control and receive up to 255 Alarms
• Virtual Calculated Alarms via MicroC built-in language
   E.g. Fire alarm If CO > 3.6 ppm
• Relay switching (open/close) when alarm fired
   E.g. Fire alarm If SO2 > 550 ppb and also switch relay 3 (close valve)
• Send email and/or SMS when alarm fired
Operating Temperature
• 15º C - 40º C
Power Requirements
• 100 vac, 115 vac, 220-240 vac +/-10% @ 236W
Size and Weight
• 415,45 mm (W) x 43,18 mm (H) x 508 mm (D), 7 kg
 

 
Dock Norte Argentina:
Cochabamba 477. Buenos Aires (1150AAE). Argentina. Tel: 54.11.4.307.8363 - 54.11.4.361.5807